How to start the Gcode file via Modbus TCP?
Firmware version: V2.4.0+
UFactory version: V2.4.0+
Holding Registers:
function code: 0x10
registers: 0x40
It will only trigger the Gcode file under the modbus_tcp folder.
Example to start 1 Gcode file
Start 1 Gcode file named 00020.
Send: 00 01 00 00 00 09 01 10 00 40 00 01 02 00 14
00 01 00 00: fixed
00 09: data length
01: ID, fixed
10: function code
00 40: register address
00 01: trigger 1 Blockly project
02: data length
00 14: Gcode file name
Example to start 2 Gcode files
Start 2 Blockly projects named 00001 and 00032.
Send: 00 01 00 00 00 0B 01 10 00 40 00 02 04 00 01 00 32
00 01 00 00: fixed
00 0B: data length
01: ID, fixed
10: function code
00 40: register address
00 02: trigger 2 Blockly projects
04: data length
00 01: Gcode file named 00001.txt
00 32: Gcode file named 00050.txt