How to start the Blockly project via Modbus TCP?
Firmware requirements
- Firmware Rversion: V1.12.0+
- UFactory version: V1.12.0+
Holding Registers:
- function code: 0x10
- registers: 0x30
Example to start 1 Blockly project
Start 1 Blocky project named 00030.
00 01 00 00 00 09 01 10 00 30 00 01 02 00 1E
- 00 01 00 00: fixed
- 00 09: data length
- 01: ID, fixed
- 10: function code
- 00 30: register address
- 00 01: trigger 1 Blockly project
- 02: data length
- 00 1E: Blockly project name
Example to start 2 Blockly projects
Start 2 Blockly projects named 00001 and 00012.
00 01 00 00 00 0B 01 10 00 30 00 02 04 00 01 00 0C
- 00 01 00 00: fixed
- 00 0B: data length
- 01: ID, fixed
- 10: function code
- 00 30: register address
- 00 02: trigger 2 Blockly projects
- 04: data length
- 00 01: Blockly project named 00001
- 00 0C: Blockly project named 00012